View All D-VXR-DY-23 Actual Exam Questions, Answers and Explanations for Free
D-VXR-DY-23 Exam Free Practice Test with100% Accurate Answers
NEW QUESTION # 137
What is a supported witness configuration for a 3+3+1 VxRail Stretched Cluster?
- A. vSAN Witness appliance with customer provided license
- B. Physical ESXi host with multiple VxRail clusters as witness
- C. Physical ESXi host with included cluster license
- D. vSAN Witness appliance or a physical ESXi host
Answer: D
NEW QUESTION # 138
Refer to the Exhibit which shows a red box around a node PSNT.
What is a characteristic of the node marked by the red box?
- A. VxRail Primary node hosting the VxRail Manager VM.
- B. VxRail node that can be excluded from the initial VxRail build.
- C. VxRail Primary node hosting the NTP and DNS servers.
- D. VxRail node hosting the DNS server.
Answer: A
NEW QUESTION # 139
In addition to the VxRail YouTube video, links to what resources should the SE send to the customer, according to the VxRail PEQ Engagement Details worksheet?
- A. VxRail vCenter Server Planning Guide VxRail Network Guide
- B. VxRail QuickStart Guide VxRail Network Guide
- C. VxRail QuickStart Guide Network Validation Tool
- D. VxRail vCenter Server Planning Guide Network Validation Tool
Answer: C
NEW QUESTION # 140
In a 24 node Stretched Cluster VxRail deployment, what is the acceptable Rout Trip Time (RTT) latency between sites?
- A. Primary to witness site RTT latency: 50 ms
Secondary to witness site RTT latency: 50 ms
Primary to secondary site RTT latency: 6 ms - B. Primary to witness site RTT latency: 75 ms
Secondary to witness site RTT latency: 75 ms
Primary to secondary site RTT latency: 1 ms - C. Primary to witness site RTT latency: 10 ms
Secondary to witness site RTT latency: 10 ms
Primary to secondary site RTT latency: 10 ms - D. Primary to witness site RTT latency: 75 ms
Secondary to witness site RTT latency: 150 ms
Primary to secondary site RTT latency: 5 ms
Answer: B
NEW QUESTION # 141
How should an administrator manually validate the DNS readiness of a customer network?
- A. Generate a Network PEQ
- B. Run nslookup on server FQDN and IP
- C. Ping the default gateway of the management VLAN
- D. Run a traceroute to the DNS server
Answer: B
NEW QUESTION # 142
The vSAN Health Check of a VxRail cluster is reporting errors about the stats.db object.
What could be a possible cause of this problem?
- A. vSAN Health Service is disabled
- B. vSAN Performance Service is not enabled
- C. vSAN Performance Service is not enabled on one of the ESX nodes
- D. There are inaccessible/unhealthy vSAN objects
Answer: B
NEW QUESTION # 143
What is a consideration for using link aggregation on the Top of Rack (ToR) switch for a VxRail?
- A. Should always be configured for VxRail node ports to allow for failover
- B. Should not be used for VxRail node ports, but can be used for uplink and ISL
- C. Is not supported on the VxRail ToR switch
- D. Can be configured for any connectivity, but are not required
Answer: B
NEW QUESTION # 144
A VxRail deployment has just been completed but the vSAN performance statistics are not available for the cluster or virtual machines.
What is the reason for this situation?
- A. vSAN performance hot-fix has not been applied
- B. Data has not been populated
- C. Performance service has not been manually enabled
- D. Monitoring policy has not been created
Answer: D
NEW QUESTION # 145
You are asked to cable up a VxRail G Series cluster to a redundant pair of 1/10G switches.
What is the cabling best practice for this configuration?
- A. Cable ports 1 and 3 to one switch. Cable ports 2 and 4 to the other switch.
- B. Cable ports 1 and 2 to one switch. Cable ports 3 and 4 to the other switch. Cable BMC from node 1 and 2 to one switch. Cable BMC from node 3 and 4 to the other switch.
- C. Cable ports 1 and 3 to one switch. Cable ports 2 and 4 to the other switch. Cable BMC from node 1 and 3 to one switch. Cable BMC from node 2 and 4 to the
- D. Cable ports 1 and 2 to one switch. Cable ports 3 and 4 to the other switch.
Answer: C
NEW QUESTION # 146
What is a requirement for the Top of Rack (ToR) switches used in a VxRail implementation?
- A. MLD Querier
- B. EtherChannel
- C. LACP
- D. IPV4 and IPV6 Multicast
Answer: D
NEW QUESTION # 147
Which options can be checked by the Network Validation Tool for VxRail?
- A. Network Services, ToR Switches, and Storage Networks
- B. ToR Switches, Upstream Switches, and Storage Networks
- C. Network Services, ToR Switches, and Upstream Switches
- D. Network Services, Upstream Switches, and Storage Networks
Answer: C
NEW QUESTION # 148
What is a valid 2-node VxRail cluster configuration?
- A. 2x 1 GbE and 2x 10 GbE in a direct-connect configuration and external vCenter
- B. 2x 10 GbE and 2x 25 GbE in a switch configuration and external vCenter
- C. 2x 10 GbE and 2x 25 GbE in a direct-connect configuration and internal vCenter
- D. 2x 1 GbE and 2x 10 GbE in a switch configuration and internal vCenter
Answer: A
NEW QUESTION # 149
An implementation engineer places a VxRail node into maintenance mode using the Ensure accessibility setting.
What is the engineer likely planning to do?
- A. Extensive maintenance
- B. Shutdown of an entire cluster
- C. Permanent removal of host from cluster
- D. Temporary maintenance
Answer: D
NEW QUESTION # 150
Where is the VxRail Documentation Quick Reference List located?
- A. Dell Technologies Support Page
- B. Dell Technologies Central
- C. VxRail Configuration Portal
- D. Dell Technologies SolVe Online
Answer: A
NEW QUESTION # 151
An infrastructure system audit will begin in two weeks All data center devices will be checked to ensure they contain the installed patches and configurations. A system engineer will update the VxRail hosts with the latest patches and remediate security vulnerabilities.
What troubleshooting resource can a user receive from Dell and use proactively to help perform the remediation tasks?
- A. Advisories
- B. SolVe Online
- C. KB articles
- D. Log files
Answer: D
NEW QUESTION # 152
Which command will create a daily local backup of the VxRail Manager configuration and important log files?
- A. python /etc/vmware/backup_config/vxm_backup_restore.py -b --period daily --keeplog
- B. python /mystic/vxm_backup_restore/vxm_backup_restore.py -c --period daily --keeplog
- C. python /mystic/vxm_backup_restore/vxm_backup_restore.py -b --period daily --keeplog
- D. python /tmp/backup/vxm_backup_restore/vxm_backup_restore.py -c --period daily --keeplog
Answer: B
NEW QUESTION # 153
A VxRail API request has been executed and the user account does not have vCenter privileges to perform the task What code is returned?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: A
NEW QUESTION # 154
What is the purpose of the As-Built Configuration Generator?
- A. Create the customer deliverable documentation of the Dell EMC product/solution implementation
- B. Capture and generate the installation workflow for review in the event of a failed deployment
- C. Provide advanced control grouping for Stretched Clusters
- D. Keep a record of all spare nodes, not yet added to a VxRail Cluster
Answer: A
NEW QUESTION # 155
Where is the VxRail Manager pre-installed on a newly shipped, 4 node VxRail Model G410 system?
- A. Node with the highest serial number
- B. Bottom-right node from the front
- C. First node
- D. All nodes
Answer: C
NEW QUESTION # 156
......
D-VXR-DY-23 dumps Free Test Engine Verified By It Certified Experts: https://guidetorrent.dumpstorrent.com/D-VXR-DY-23-exam-prep.html