DES-6322 Exam Questions Get Updated [2023] with Correct Answers [Q46-Q68]

Share

DES-6322 Exam Questions Get Updated [2023] with Correct Answers

Practice DES-6322 Questions With Certification guide Q&A from Training Expert DumpsTorrent


EMC DES-6322 exam is designed to test the expertise and knowledge of candidates in the area of VxRail implementation. DES-6322 exam is targeted towards professionals who are seeking to demonstrate their skills in implementing and configuring VxRail solutions. DES-6322 exam is a specialist-level certification, which means that candidates must have a solid understanding of the concepts and technologies involved in VxRail implementation.

 

NEW QUESTION # 46
An implementation engineer is tasked with setting up RecoverPoint for VMs on a new 4-node E Series VxRail duster How many VMs are licensed to be protected on the cluster?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C


NEW QUESTION # 47
After implementation, the implementation engineer observes errors from both VxRail Manager and vCenter Server.
Dell EMC support has requested a log bundle containing only the required log files.
Using the simulator, create and download a log bundle for Dell EMC support.
When you have finished, continue to the next question.

Answer:

Explanation:






NEW QUESTION # 48
What is a supported witness configuration for a 3+3+1 VxRail Stretched Cluster?

  • A. Physical ESXi host with included cluster license
  • B. vSAN Witness appliance or a physical ESXi host
  • C. vSAN Witness appliance with customer provided license
  • D. Physical ESXi host with multiple VxRail clusters as witness

Answer: B


NEW QUESTION # 49
Match each VxRail data protection solution with its functionality.

Answer:

Explanation:


NEW QUESTION # 50
During the activation of Internal SRS, the implementation engineer receives a message that the deployment has failed What is a possible cause?

  • A. Witness Gateway not configured following Dell best practices
  • B. SRS VE Gateway on the same subnet as the VxRail Manager
  • C. Site ID mismatch between the IB database and the SRS Wizard
  • D. VxRail status already set to installed' in IB database

Answer: B


NEW QUESTION # 51
What is the correct CLI command to collect only the vCenter logs on VxRail Manager

  • A. generateLogBundle.py -c
  • B. generateFullBundle.py -v
  • C. vc-support.sh -v
  • D. vc-support-bundle.sh -c

Answer: A


NEW QUESTION # 52
Match each VxRail configuration with its related characteristic.

Answer:

Explanation:


NEW QUESTION # 53
An implementation engineer is deploying a new VxRail cluster What should they confirm before installing the hardware?

  • A. Power distribution supports only the power rating of a single node
  • B. Redundant power zones exist with adequate power cables
  • C. At least 24 in (61 cm) of clearance exists in front of and behind the cabinet
  • D. Service laptop is on the same IP network as the iDRACs

Answer: A


NEW QUESTION # 54
A customer has decided that they will be using the Spanning Tree protocol in their Dell EMC ToR switches How should the switch ports used for VxRail be configured to achieve a successful deployment?

  • A. Enable MLD snooping and querier
  • B. Enable link aggregation for all ports
  • C. Set the port type to edge
  • D. Set the port mode to access

Answer: D


NEW QUESTION # 55
An implementation engineer is configuring the network firewall to support a VxRail installation. Where can they find the necessary firewall rules?

  • A. VxRail Configuration Portal
  • B. Rack worksheet of the Network PEQ
  • C. Network Validation Tool
  • D. As-Built Configuration Report

Answer: D


NEW QUESTION # 56
An implementation engineer is deploying a new VxRail cluster What should they confirm before installing the hardware?

  • A. At least 24 in (61 cm) of clearance exists in front of and behind the cabinet
  • B. Service laptop is on the same IP network as the iDRACs
  • C. Redundant power zones exist with adequate power cables
  • D. Power distribution supports only the power rating of a single node

Answer: C


NEW QUESTION # 57
What is validated by running the Proactive Network Performance test in vCenter on a VxRail cluster?

  • A. Latency measurement between DCs for Stretched Clusters
  • B. Network configuration and performance for vSAN
  • C. Network performance for virtual machines
  • D. Latency and bandwidth measurement to the witness host

Answer: B

Explanation:


NEW QUESTION # 58
From what environment must a network administrator run VxRail network validation?

  • A. VxRail Deployment Wizard
  • B. Windows PowerShell command prompt
  • C. Same subnet as VxRail Management Network
  • D. Top of Rack switches

Answer: C

Explanation:


NEW QUESTION # 59
An implementation engineer is configuring the network firewall to support a VxRail installation. Where can they find the necessary firewall rules?

  • A. VxRail Configuration Portal
  • B. Network Validation Tool
  • C. Rack worksheet of the Network PEQ
  • D. As-Built Configuration Report

Answer: C

Explanation:


NEW QUESTION # 60
An implementation engineer is deploying a VxRail cluster with the VxRail Deployment Wizard Which user accounts must be defined for VxRail Manager?

  • A. VxRail Manager root account VxRail Manager service account
  • B. vCenter root account VxRail Manager service account
  • C. VxRail Manager root account vCenter service account
  • D. VxRail Manager service account vCenter service account

Answer: A


NEW QUESTION # 61
A VxRail solution will be deployed with the embedded vCenter and an external DNS At a minimum, for which components must DNS records be created?

  • A. vCenter Server Platform Services Controller, and VxRail Manager
  • B. vCenter Server, ESXi hosts, and VxRail Manager
  • C. ESXi Hosts, VxRail Manager and iDRAC
  • D. vCenter Server Platform Services Controller, and iDRAC

Answer: B


NEW QUESTION # 62
What is a benefit of using the VxRail REST API?

  • A. Remote upgrades of iDRAC related software only
  • B. Automated security audits of VxRail clusters
  • C. Programmatically gather VxRail system health
  • D. Polling for vSAN performance statistics

Answer: C


NEW QUESTION # 63
An implementation engineer is expanding an existing VxRail S Series cluster with an additional node. The version of the node is not at the current cluster level but is compatible.
What procedure would result in the quickest node addition?

  • A. VxRail Node Imaging Management
  • B. Factory Reset
  • C. Compute node expansion
  • D. RASR Factory Image Upgrade

Answer: C


NEW QUESTION # 64
In a VxRail Stretched Cluster deployment of 8 nodes on between sites?

  • A. Primary to Witness site RTT: < 150 ms Secondary to Witness site RTT: < 150 ms Primary to Secondary site RTT: < 10 ms
  • B. Primary to Witness site RTT: < 250 ms Secondary to Witness site RTT; < 250 ms Primary to Secondary site RTT: < 5 ms
  • C. Primary to Witness site RTT: < 200 ms Secondary to Witness site RTT < 200 ms Primary to Secondary site RTT: < 10 ms
  • D. Primary to Witness site RTT: < 200 ms Secondary to Witness site RTT: < 200 ms Primary to Secondary site RTT: <: 5 ms

Answer: A


NEW QUESTION # 65
Match each VxRail, data protection solution with its functionality.

Answer:

Explanation:


NEW QUESTION # 66
What is validated by running the Proactive VM Creation test in vCenter on a VxRail cluster?

  • A. vSAN operates successfully
  • B. vSAN has sufficient storage capacity
  • C. Network firewalls are configured correctly
  • D. Network performance is sufficient

Answer: A


NEW QUESTION # 67
A VxRail implementation engineer is validating the network environment with NVT. The proposed switch configuration is shown in the exhibit. The ToR Switch information file is available.
Use the VxRail simulator to set up NVT for switch validation. Import the switch Information and tag the ports based on the exhibit.

Answer:

Explanation:
Pending
Send your suggestions for this question.


NEW QUESTION # 68
......

Prepare Top EMC DES-6322 Exam Audio Study Guide Practice Questions Edition: https://guidetorrent.dumpstorrent.com/DES-6322-exam-prep.html